Chinese | English
Home Brand EUCHNER safety switch

Euchnersafety switch CET2-AR-CRA-CH-50X-SH-110206

Product Description:

Add Inquiry

Mechanical values and environment:

Building material alloy - die casting

Weight 0.6 kg

Environmental temperature -20 80 ° C

Protection level IP67

Mechanical life 1 × 10 6

Contact material: silver alloy, flash gold

Switching principle: slow acting switch contacts

Any installation direction

Number of forced drive contacts for protective lock monitoring: 2

Number of normally open contacts for door lock monitoring: 2

Size 3 × M20 × one point five

Approaching a maximum speed of 20 meters/minute

Maximum action frequency 1200 1/hour

Door lock principle Open circuit current principle

Locking force F max 3000 Newton

Locking force F Zh 2300 Newton

Holding force 20 Newton

Pullout force 30 Newton

Driving force 35 Newton

Minimum insertion depth of 24.5 mm

Thermal rated current I th 4

Use categories AC-15 4A 230V, DC-13 4A 24V according to EN 60947-5-1

The working voltage of the electromagnet is AC/DC 24V -15%+ 10%

Short circuit protection (fuse) according to IEC 60269-1 4A gG

Rated insulation voltage U i 250 V Rated impulse withstand voltage U imp 2,5 kV

Switching voltage at 10mA 12 volts per minute

Switching current at 24V 1 mA per minute

Energy consumption 8 watts

Solenoid duty cycle 100%

Connection section 0,34 1,5 square millimeters

Reliability values in accordance with EN ISO 13849-1

Door lock monitoring and safety protection position B10 D 11,5 x 10 6

Features include:

Thermal rated current Ith: 4A

Rated insulation voltage Ui: 250 V

Rated impulse withstand voltage Uimp: 1.5 kV

Usage category: AC-15 4A 230V/DC-13 4A 24V

Working voltage of electromagnet: AC/DC 24 V -15% -+10%

Switching voltage: minimum. At 10mA, 12V

Switching current: minimum. At 24V 1 mA

Connection rating: 10 W

Connection: 1 x plug connector BHA10

LED indicator light: The working voltage corresponds to the solenoid voltage

Shell material: Shell: Anodized die-casting alloy

Contact material: silver alloy, flash gold

Environmental temperature: -25-80 ° C

Protection level: IP65

Switch principle: Inching switch contacts

Installation direction: Any

Number of positive drive contacts for door position: 4

Number of positive drive contacts for door lock monitoring: 4

Approach direction: Drive head left C

Approach speed: max.20 m/min

Action frequency: max.1200 1/h

Door lock principle: closed circuit current principle

Locking force Fmax: 2000 N

Locking force FZh: 1500 N

Lid: Red

LED indicator light: The working voltage corresponds to the solenoid voltage